Doors
The Doors menu provides an overview of the types (hinged doors, automatic doors) and distribution
of accesses. Furthermore, you can release calls, define door signals and determine door times.
[Direct access: CMD -> 7037 or 7047 or 7190 -> OK]
Parameter
[Direct access]
Query whether one door can only open at a time in a
through car.
Hinged doors 1
[CMD -> 7038 ->
7045 -> OK]
Query whether hinged doors (side 1) are to be
enabled. By choosing “Yes”, the parameters for
hinged doors are released. Press > to go to pages with
parameters for hinged door assignment side 1. For
further information regarding this submenu, check
the corresponding chapter.
Hinged doors 2
[CMD -> 7039 ->
7046 -> OK]
Query whether hinged doors (side 2) are to be
enabled. By choosing “Yes”, the parameters for
hinged doors are released. Press > to go to pages with
parameters for hinged door assignment side 2 (page
39). For further information regarding this submenu,
check the corresponding chapter.
Door 1 signals
[CMD -> 7042 or
7169 OK]
Call of page 42 which serves to determine the door
control signals (e.g. light curtains, closing force
limiter). For further information regarding this
submenu, check the corresponding chapter.
Door 2 signals
[CMD -> 7043 or
7175 -> OK]
Call of page 43 which serves to determine the door
control signals (e.g. light curtains, closing force limiter,
etc). For further information regarding this submenu,
check the corresponding chapter.