EasyManua.ls Logo

Kleemann GENIUS20 - Doors; Hinged Doors 1; Door 1 Signals

Default Icon
233 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
59
MA06-03-1-01
Menu
Doors
The Doors menu provides an overview of the types (hinged doors, automatic doors) and distribution
of accesses. Furthermore, you can release calls, define door signals and determine door times.
[Direct access: CMD -> 7037 or 7047 or 7190 -> OK]
Parameter
[Direct access]
Description
Default
value
Value
Range
Exclusive lock
Query whether one door can only open at a time in a
through car.
NO
YES/NO
Hinged doors 1
[CMD -> 7038 ->
7045 -> OK]
Query whether hinged doors (side 1) are to be
enabled. By choosing Yes”, the parameters for
hinged doors are released. Press > to go to pages with
parameters for hinged door assignment side 1. For
further information regarding this submenu, check
the corresponding chapter.
YES/NO
Hinged doors 2
[CMD -> 7039 ->
7046 -> OK]
Query whether hinged doors (side 2) are to be
enabled. By choosing “Yes”, the parameters for
hinged doors are released. Press > to go to pages with
parameters for hinged door assignment side 2 (page
39). For further information regarding this submenu,
check the corresponding chapter.
YES/NO
Door 1 signals
[CMD -> 7042 or
7169 OK]
Call of page 42 which serves to determine the door
control signals (e.g. light curtains, closing force
limiter). For further information regarding this
submenu, check the corresponding chapter.
Door 2 signals
[CMD -> 7043 or
7175 -> OK]
Call of page 43 which serves to determine the door
control signals (e.g. light curtains, closing force limiter,
etc). For further information regarding this submenu,
check the corresponding chapter.