131
MA06-03-1-01
Menu
Parameter
[Direct access]
Description
Default
value
Value
Range
In the shut-down landing, the door is opened
and closed when the idle time has elapsed.
The lift car light is switched off if the
corresponding parameter "Switch car light" in
the "Relay addresses" parameter set is
programmed.
When the key is removed, the lift immediately
changes to the original operating mode or
possibly to an operating mode activated in the
meantime.
I: SO input control
cab.
Definition of an input for the switch-off function in
the control cabinet. The function is analogous to the
above-mentioned function " I:SO key floor".
*SO key floor
signal:
Selection whether the inputs for the switch-off
signal are applied by normally close contacts or
normally open contacts.
N.O./N.C.
Door open in
landing
Selection whether the doors are to remain open or
closed after the switch-off function is enabled.
NO
YES/NO
Group
[CMD -> 7073 ->
OK]
Query whether several cars are to run as a lift group.
By choosing “YES” the group parameters are made
visible.
YES/NO
I:Start SO with
pulse
Definition of an input for switching-off the
installation (controller/light off) via a temporary
impulse (>10 msec.) e.g. by enabling a push-button.
Usually, this is carried out with a key switch in
landing or control cabinet.
I:End SO with
pulse
Definition of an input for switching back on; likewise
performed via an impulse.
Floor: Call
Definition of the first landing to be approached after
initializing the switch-off function, in order to urge
people to leace the car. It is usually the landing in
which the switch-off key is located.
2
1-max.
landing
Floor: Switch off
Definition of a landing where the car is parked after
initializing the switch-off function.
2
1-max.
landing
O:SO active
Definition of an output for optic signaling of the
active switch-off function.