Parameter
[Direct access]
Change the page to set door mask into
evacuation mode. For further
information regarding this submenu, check
the corresponding chapter.
Query whether the system is to change to
normal operation after the evacuation travel
although the evacuation mode is active
(Delay time 10 sec. after termination of
evacuation)
When selecting “YES”, further operation is
possible in accordance with the parameter
settings described under “Number of
movements”. When selectiong “NO”, the lift
will shut down in the evacuation landing.
Limited further operation is however stil
possible via parameter: “I:Free after ET”
Definition of an input for releasing travels
after an executed evacuation given certain
preconditions are fulfilled. This parameter is
only available, when free after evacuation
travel is set to “No”. (see above) If this input
is activated, only car calls are permissible.
Hence, travels are released/permitted under
the conditions of the parameter “Number of
movements”.
This parameter serves to determine the
number of travels which are allowed to be
conducted under emergency power supply.
When the maximum number of travels is
reached, this will be indicated at the end of
the last run by emitting an acoustic signal for
10 sec.
Setting this parameter 0 allows infinite
number of travels.
Determination of an input in order to define
the intended evacuation direction
(upwards). Usually the signal is given by the
frequency inverter.
Determination of an input in order to define
the intended evacuation direction
(downwards). Usually the signal is given by
the frequency inverter.
Definition of an output for visual signalling of
the active evacuation mode.
Query whether an evacuation is to be
initiated by the inverter in DCP in case the
inverter has detected a supply
interruption/phase error.