Page #99 background imageLoading...
Page #99 background image
99
MA06-03-1-01
Menu
Mode
The status menu serves to define operating states (see pictures below). By activating the operating
states, you can enable or disable accesses and calls, invert door parking positions and change parking
levels.
Order or priority from lowest to highest:
Normal operation Special travel 1 Special travel 2 Special travel 3 Special travel 4 Special
travel 5 Special travel 6 Evacuation Fire case Fire service travel Shutdown
[Direct access: CMD -> 7032 -> 7085 -> 7033 -> 7157-> OK]
Parameter
[Direct access]
Description
Default
value
Value
Range
Release/Block calls door
1
Query whether calls (landings) are released or
blocked. Select "NO" to change to "YES". Press >
to go to pages with call release parameters
YES/NO