EasyManuals Logo

Kleemann GENIUS20 User Manual

Default Icon
233 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
23
MA06-03-1-01
Menu
Parameter
[Direct access]
Description
Default
value
Value
Range
Building access
[CMD -> 7001-> OK]
Determination of the access-related shaft situation on
door sides 1 and 2. A maximum of 64 accesses are
possible per door side. For further information regarding
this submenu, check the corresponding chapter.
Main landing
Defines the main landing and thus influences the parking
behaviour and the call processing. If the parking mode
(see parameter "Parking mode") is selected, the main
landing is preferentially occupied.
In the case of single-button systems with direction-
dependent call cancellation (see parameter "Direction-
dependent call cancellation") the main landing serves to
determine the collective direction. All landing calls in
landings below or in the main landing are effected
upwards. Correspondingly, the landing calls above the
main landing are effected downwards.
In the case of two-button groups with different numbers
of landings in the lower section, setting the main landing
has the effect that all the landing calls below or in the
main landing are assigned to the car covering the lower
section.
2
1-64
Landing labels
[CMD ->7018-> OK]
Determines the landing names for the Bus displays on
page 18. For further information regarding this
submenu, check the corresponding chapter.
Display moving text
[CMD -> 7006 ->
7007 -> OK]
Determines the scrolling texts for display on the bus
system. For further information regarding this submenu,
check the corresponding chapter.
EN 81-20
Serves to make special settings for the EN81-20
standard. For further information regarding this
submenu, check the corresponding chapter.
Lift attendant
For further information regarding this submenu, check
the corresponding chapter.
t: Starting delay (ms)
Determines a delay time in milliseconds after which the
travel is to be started.
0
0 - 4000
Travel
[CMD -> 7029-> OK]
Setting of travel values (Change to page 29). For further
information regarding this submenu, check the
corresponding chapter.
Deceleration
[CMD -> 7030 or
7036 -> OK]
Setting of deceleration values (change to page 30). For
further information regarding this submenu, check the
corresponding chapter.
Deceleration control
[CMD -> 7207 ->OK]
Setting of deceleration control (change to page 207). For
further information regarding this submenu, check the
corresponding chapter.