Parameter
[Direct access]
only software
[CMD -> 7221-> OK]
Selection for recovering solely GENIUS20 software. Any other
software remains unaffected. Depending on the files available, the
GENIUS20 software versions in the different memory medium
folders are displayed here for selection and direct activation.
only parameter
[CMD -> 7222-> OK]
Selection for recovering saved parameters. Any other software
remains unaffected.
Information: If parameters are saved in a Temp-subdirectory, these
procedures are conducted from the menu. The desired parameter
configurations which are to be recovered can be selected here and
re-saved to the processor.
only history
[CMD -> 7223-> OK]
Selection for recovering saved logs. Any other software remains
unaffected. Depending on the files available, the log-files in the
different memory medium folders are displayed here for selection
and direct activation.
only IAP
[CMD -> 7224-> OK]
Selection for recovering the processor’s saved IAP (boot loader). Any
other software remains unaffected. Depending on the files
available, the IAP’s in the different memory medium folders are
displayed here for selection and direct activation.
only Bus Driver
[CMD -> 7225-> OK]
Selection for recovering the bus driver on the processor board. Any
other software remains unaffected. Depending on the files
available, the Genius bus driver in the different memory medium
folders are displayed here for selection and direct activation.
Ηand terminal
[CMD -> 7226-> OK]
Selection for recovering software of the hand terminal. When
running the update, please do not disconnect the hand terminal,
since otherwise the update might be incomplete. Any other
software remains unaffected. Depending on the files available, the
hand terminal softwares in the different memory medium folders
are displayed here for selection and direct activation.
Alternatively, you can use the direct command 692 to list the backups available on the micro-SD card.
Enter command 692 plus the required backup number (= above-mentioned serial number) to load the
backup (e.g. 692001).
Use command 693 and the serial backup number to restore only the parameters (e.g. 693002).