146
MA06-03-1-01
Menu
Parameter
[Direct access]
Description
Default
value
Value
Range
panel which serves to activate the
“dangerous goods” mode.
1.I: Landing key DS1
1. Address input on a bus module in each
landing where either I/O or dangerous
goods keys are connected for activating
the mode.
1.I:Close doors DS1
1.Adress input on a bus module in each
landing. It defines at which I/O the doors
are to be closed and travel to be started
with the signal “Dangerous Goods Door-
close” (Only for Australian dangerous
goods mode)
1.I: Landing key DS2
1. Address input on a bus module in each
landing where either I/O or dangerous
goods keys are connected for activating
the mode.
1.I:Close doors DS2
1.Adress input on a bus module in each
landing. It defines at which I/O the doors
are to be closed and travel to be started
with the signal “Dangerous Goods Door-
close” (Only for Australian dangerous
goods mode)
O:Dangerous Goods
Output to signal an active dangerous-
goods transport.
O:Text Dangerous Goods
Output which serves to define a
conventional audio-response for an active
Dangerous Goods transport. For this
purpose a pulse of 1 sec. duration is issued.
Speech text-number
Number of the audio-response text which
is to be issued via a BUS-audio response
in the event of a dangerous goods
transport.
70
T:Reserve time (s)
Maximum reservation time until actuation
of the car key for an activated dangerous
goods transport in the landing. After this
this time interval elapses, normal mode is
restored.
30
0-999 s