Operation via command level
The following table provides an overview of possible input commands which can be entered using
the "CMD" button at the bottom of the display. Each command input must be confirmed using the
"OK" button. "CL" serves to delete the entry. Pressing the "CMD" button again deletes the input
range.
Command overview
Door 1 is opened regardless of the door
open permission.
Door 2 is opened regardless of the door
open permission.
Indication of DCP information in the status
text window.
Doors are blocked or released.
Switch off landing control
Enables or disables the landing control. No
calls in the landings are accepted.
Serves to simulate car and landing calls.
The controller processes the calls.
Serves to simulate the recall control by
means of the software. Safety circuit
equipment will not be jumpered.
Only in case of homelifts. Serves to
simulate TSG activation and RSB reset by
means of the software.
If a modem is connected and configured in
the menu, it can be re-initialised.
Show (relative) absolute
encoder values
If enabled, the absolute encoder values are
displayed in the controller status window
relative to the lowest landing.3
Show (actual) absolute
encoder values
If enabled, the actual absolute encoder
values are displayed in the controller
status window (value on magnetic tape).
DCP:
Send / do not send package
I7.
Package I7 provides the inverter with the
estimated path value for the upcoming
travel.
The lift is called to landing xx. The car calls
of a selective second door side follow
those of the first door side.
15* = car call for landing
5