12
MA06-03-1-01
Menu
2xx
Upwards landing call for
landing xx
Makes an upwards landing call, depending
on the call release.
25* = upwards landing
call for landing 5
3xx
Downwards landing call for
landing xx
Makes a downwards landing call,
depending on the call release.
35* = downwards
landing call for landing
5
401
Relay test
Checks all relay outputs as well as travel
signal outputs to the frequency inverter.
403
Display the SD card data
Displays any folders and files available on
the SD card.
404
Display test
Checks the GENIUS20 bus displays.
405
I/O test
Checks the IO32 card on the processor
board for functioning.
600
Save data
Saves parameter and settings to the
internal flash memory.
601
Data transmission to
displays
All set display characters per landing are
transmitted to the displays connected to
the GENIUS20 bus.
6060
Controller restart
Restart of the control computer is
enforced.
692
Display backup folder
Displays all complete backups (folders) on
the SD card.
697
Lift software backup
Backs up the current lift software on the SD
card if no current backup is available.
698
Current software version
Displays the current software version.
698xxx
Restore lift software
Restores the software saved on the SD
card in the root - for this purpose, the file
name index (3-digit number) must be
entered.
Restore software with
suffix 001 using
698001*
700
Delete UCM error / UCM
test
Deletes the current UCM error.
The UCM test mode can
only be enabled if the
car is in the zone and no
UCM error is present.
701
Travel to upper final limit
switch
Car travels to upper final limit switch (also
required for Certification).
702
Travel to lower final limit
switch
Car travels to lower final limit switch (also
required for Certification).
703
Certification mode
704
UCM valve test
Triggers a UCM valve test for hydraulic
systems which, in case of successful test,
must shut down for UCM fault.
7xxx
Call parameter page
Enter page number (three digits) to go to
the associated parameter page.
800
Delete error
Deletes the current error.
8xxy
Set I/O at the landing bus
module
Landing bus:
xx is the address of the bus module
(between 00 and 63)
y is the I/O number