The current program as well as the error log will be saved in the next step. Enter 691 for this purpose
and confirm with OK. Now the lift software can be updated by entering 698 and the backup number
(e.g. 000). Click OK again to confirm. You will be asked a few questions which you should usually answer
YES. The controller now runs the fully automatic update process. As soon as the main menu is displayed
again, the update is completed.
Here a short update overview:
Main menu → CMD → 6060 OK → main menu → CMD → 691 OK → 698000 OK
Checking the update
Quickly check the most important parameters after the update. They are:
❑ lift type
❑ absolute encoder values
❑ door masks
❑ building accesses
They are visible in the general parameters. If all parameters match the expected values, the system
can be put into service again.