124
MA06-03-1-01
Menu
Parameter
[Direct access]
Description
Default
value
Value
Range
DS1 open mask
[CMD -> 7178-> OK]
Change to the page to set door masks for
firemen mode. For further information
regarding this submenu, check the
corresponding chapter.
Open DS1 on floor
This parameter serves to determine whether
DS1 in the firemen-landing is to be opened in
the case of a firemen-travel. This parameter is
queried only if both doors in the firemen-
landing are activated at the FT-door mask.
NO
YES/NO
Open DS2 on floor
This parameter serves to determine whether
DS2 in the firemen-landing is to be opened in
the case of a firemen-travel. This parameter is
queried only if both doors in the firemen-
landing are activated at the FT-door mask.
NO
YES/NO
Exclusive lock
Query whether in firemen mode may always
only one door be opened even in case of the
possibility to load through directly. For firemen
lifts according to EN 81-72:2015 this is
required, therefore the parameter must
necessarily set “YES”.
YES
YES/NO
O:Text FT
Definition of an output for visual signalling of
the active firemen mode.
FT text on speech mo.
Selection whether a note concerning the active
firemen mode is to be put out via the bus voice
output.
YES
YES/NO
O:FT active
Definition of an output to signal the active
firemen mode.
1.O:DO Acknowledge
Definition of the first output used to display
the door side which is possible for opening in
the car durin firemen mode. The second door
side will automatically be assigned to the
subsequent I/O.
Reach to target
This parameter serves to determine whether
the lift has reached the FT floor in case of
activated firemen travel.
YES/NO
EN 81-72
This parameter serves to activate the
requirements of EN 81.72 standard in case of
firemen travel. In case of firemen’s elevator its
default value is yes.
YES/NO
CloseBtn deact.: D
close
Selection of the function of the door close
button. The door keeps closing when the
button is released.
YES
YES/NO
CloseBtn deact.: D stop
Selection of the function of the door close
button. The door stops when the button is
released.
NO
YES/NO
CloseBtn deact.: D
open
Selection of the function of the door close
button. The door will open again when the
button is released.
NO
YES/NO