135
MA06-03-1-01
Menu
Parameter
[Direct access]
Description
Default
value
Value
Range
IO: Visitor
Definition of an input to activate the visitor
mode. When the input is activated, the car
travels to the main floor.
Consider zero load
YES causes the lift to start in entry landing only
in the case of a detected “load” within the car.
Otherwise the lift will not move.
NO
YES/NO
Autom. car call
If the visitor control is activated, the lift moves
into the entry landing where the car call for the
visitor landing can be set automatically.
NO
YES/NO
T:Timeout (s)
When the lift is approaching the entry landing, it
is reserved to visitor travel for this maximum
time interval (in seconds).
121
0-999
IO: call with zero
load
Definition of an input for Penthouse landing call
with zero load consideration