MA06-03-1-01
Menu
Parameter
[Direct access]
Description
Default
value
Value
Range
Shaft light impulse
“YES” causes the shaft light control to switch
into pulse mode for activation of a latching
relay. Every switching of the shaft light at
Genius causes an impulse with 700 ms to be
issued. The shaft light relay KSL will only be
controlled for the amount of time given by
this impulse. There will be no notification
about the shaft light at the controller.
T:Simulation time
(min)
Definition of the simulator runtime after
having been started. When this time (in
seconds) has elapsed, the simulation is
terminated and landing call control and door
blocking are reset automatically.
20
I:Page Printscreen
This provides the possibility to trigger a
printscreen using a defined I/O port. On the
touchscreen this is done by simply pressing
the Genius hashtag. For this purpose, an SD
card must be available in the hand terminal.
Demo mode
This serves to provide the possibility to run
the controller in demo mode.
0 = Demo mode disabled
1 = Operation with simulator
10 = Operation without simulator
0
Simulation type
Internal for testing:
If [bit 0 = 1] is set, the car will always stop at
the beginning of the zone when going to the
next landing. Then the lift is supposed to
relevel and go to the centre of the zone.
If [bit 1 = 1] is set and landing control off and
doors are blocked, the lift will execute an
emergency stop every 2 minutes. This serves
to examine the stopping behaviour.
0
Show status page
"YES" serves to automatically indicate the
status page after the configured switching
time.
YES
YES/NO
Show display page
"YES" serves to automatically indicate the
display page after the configured switching
time.
NO
YES/NO
Show release page
"YES" serves to automatically indicate the
status page after the configured switching
time.
NO
YES/NO
T:Switch time
pages (s)
If the hand terminal is not operated, one of
the pages configured above will be displayed
after an adjustable time in seconds. If the
value is 0, none of the pages will be displayed.
60