Certification
The "Certification" menu provides functions that are useful for acceptance by authorised inspection
agencies.
Important for all inspections:
Note: Prior to any tests, the car must be cleared from any persons and secured against re-entry.
Select the depicted function in order to start it. The status is displayed by automatically changing to
the status window.
The "Reset/End certification" function triggers a controller restart. This is necessary after the test in
order to deactivate the "Certification" function.
[Direct access: CMD -> 7192 -> 7056 -> OK]
Selecting this function starts a travel to the
upper limit switch. The travel is completed
by interrupting the safety circuit (S1) when
the upper limit switch is actuated.
After leaving the limit switch (S1 is applied
again when going down), hydraulic lifts will
go to the lowest landing and stay in the out-
of-order status. Resetting is only possible by
hand (e.g. inspection, reset).
Rope-traction lifts must be removed from
the final limit switch by recall or other