184
MA06-03-1-01
Menu
Battery
In addition to the current supply voltage, the charging voltage and the state of the emergency battery
connected to terminals XK14 (+BAT; -) is displayed.
If the battery charging is switched on, this is signalled on the screen as well as the requirement for
charging and the current charging current. At the bottom there is the Menu button and the button to
change to the previous and next page.
General: A battery test is executed automatically every 8 hours. If the test is successful, everything is
ok. If not, this is displayed during each travel by "Please check BATTERY!". After 5 negative test results
the lift is switched "out of operation".