Parameter
[Direct access]
Definition of the second input for the car call button,
i.e. depending on the number of landings there are
further inputs for car calls). This defines the order of
numbering.
Definition of the first output for the car call
acknowledgement. Depending on the number of
floors, further outputs for the car call
acknowledgment follow. It is used when call &
acknowledgment are connected separately.
Query whether a car call cancellation option is
intended. This would enable passengers to cancel an
issued car call by pushing the corresponding call-
button again. A precondition for the functioning of
this option requires calls and call acknowledgments to
be connected to the controller via separate IOs. Also,
the parameter 1.O: Car-call acknowledgment must be
programmed.
Definition of an input for the start signal. In case of
lifts with two landings, no call buttons are used in the
panel. The "Start" initiates car calls.
Attention: First and second car call must be
programmed!
*Not yet implemented
Definition of an input for switching off landing
control.
Definition of an input for the full load signal. When full
load is activated, the display indicates “Full load”.
Additional text can be defined under the menu
section for scrolling texts.
Definition of an input for the overload signal. When
overload is activated, the display indicates
“Overload”. Additional text can be defined under the
menu section for scrolling texts.
Selection whether the overload signal is based on a
normally open (N.O.) or a normally close (N.C.)
contact.
Definition of an input for the zero-load signal when no
car load is performed.
Definition of the door masking in case that the I: Zero
load is activated.
Definition of a half load signal input for car loading.
Definition of an input for the activation or
deactivation of car light.
Query whether a starter is used for the activation of
car light.