Supplypowerrequirements
Observethegeneralrequirementsrelatedtothesupplypower.
Thesupplyvoltagetotheequipmentmustkeptwithin±10%oftheinstallation’snominal
voltage.
Maximumtransientvoltagevariationsonthemainswitchboard’sbus-barsarenotto
exceed-15%to+20%ofthenominalvoltage(exceptunderfaultconditions).
•Makeandmodel:KongsbergWBT
•Voltagerequirement:12–15VDC,5A
•Powersupply:
–Voltagerequirement:115/230V AC,47to63Hz,singlephase,nominal
–Maximumvoltagedeviation:15%
–Maximumtransient:20%ofnominalvoltage,recoverytime3s
–Powerconsumption:100V A(Approximately)