392616/B
49
AnEthernetswitchisrequiredifmorethanoneWBTisused.
Ajunctionboxisrequiredifthetransducercableislongerthanprovided.
Listofcables
AsetofcablesisrequiredtoconnecttheEA440unitstoeachother,andtotherelevant
powersource(s).
Cable
Type
From/ToMinimumrequirements
C1
TransducercableFromWBTtotransducer*
C2
DCpowercableFromPowersupplytoWBT**
C3
ACpowercableFromPowersupplytoACpower
outlet
**
C4
GroundcableFromWBTtovesselground
1x6mm
2
C5
EthernetcableFromWBTtoEthernetswitch
CAT5–ESTP
C6
EthernetcableFromOperatorStationto
Ethernetswitch
CAT5–ESTP
C7
ComputercableFromOperatorStationto
keyboard
**
C8
ComputercableFromOperatorStationtomouse
(oranothersimilardevice)
**
C9
GroundcableFromOperatorStationtovessel
ground
1x6mm
2
C10
ACpowercableFromOperatorStationtoAC
poweroutlet
**
Comments
1Thetransducercableisprovidedwiththetransducer.Ifyouneedtosplice
thetransducercabletomakeitlonger,observetheinformationintheenduser
documentationfortherelevanttransducer.
2ThecableissuppliedwiththeEA440delivery.
IdentifyingEA440cablesonaprojectcabledrawing
TheEA440isoftenapartofaprojectdelivery.Forsuchdeliveries,specicprojectcable
drawingsareestablishedtoshowallthemaincables,andhowthevariousproducts
areconnected.Insuchprojectcabledrawings,theEA440cablesmaybeidentied
asEA440/Cx.
Cablelayoutandinterconnections