EasyManua.ls Logo

Kongsberg EA440 - List of Cables

Kongsberg EA440
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
392616/B
49
AnEthernetswitchisrequiredifmorethanoneWBTisused.
Ajunctionboxisrequiredifthetransducercableislongerthanprovided.
Listofcables
AsetofcablesisrequiredtoconnecttheEA440unitstoeachother,andtotherelevant
powersource(s).
Cable
Type
From/ToMinimumrequirements
C1
TransducercableFromWBTtotransducer*
C2
DCpowercableFromPowersupplytoWBT**
C3
ACpowercableFromPowersupplytoACpower
outlet
**
C4
GroundcableFromWBTtovesselground
1x6mm
2
C5
EthernetcableFromWBTtoEthernetswitch
CAT5–ESTP
C6
EthernetcableFromOperatorStationto
Ethernetswitch
CAT5–ESTP
C7
ComputercableFromOperatorStationto
keyboard
**
C8
ComputercableFromOperatorStationtomouse
(oranothersimilardevice)
**
C9
GroundcableFromOperatorStationtovessel
ground
1x6mm
2
C10
ACpowercableFromOperatorStationtoAC
poweroutlet
**
Comments
1Thetransducercableisprovidedwiththetransducer.Ifyouneedtosplice
thetransducercabletomakeitlonger,observetheinformationintheenduser
documentationfortherelevanttransducer.
2ThecableissuppliedwiththeEA440delivery.
IdentifyingEA440cablesonaprojectcabledrawing
TheEA440isoftenapartofaprojectdelivery.Forsuchdeliveries,specicprojectcable
drawingsareestablishedtoshowallthemaincables,andhowthevariousproducts
areconnected.Insuchprojectcabledrawings,theEA440cablesmaybeidentied
asEA440/Cx.
Cablelayoutandinterconnections

Table of Contents

Related product manuals