WBT
Makeandmodel:KongsbergWBT
Voltagerequirement:1215VDC,5A
Asuitablepowersupplyisprovidedwiththedelivery.
Powersupply:
Voltagerequirement115/230V AC,47to63Hz,singlephase,nominal
Maximumvoltagedeviation:15%
Maximumtransient:20%ofnominalvoltage,recoverytime3s
Powerconsumption:100V A(Approximately)
Environmentalrequirements
Theseenvironmentalspecicationssummarizethetemperatureandhumidity
requirementsfortheEA440Singlebeamhydrographicechosounder.
OperatorStation
Makeandmodel:HattelandDisplayJH19T14MMC
Operationaltemperature:-15to55°C
Storagetemperature:-20to60°C
Relativehumidity:95%maximum
Degreeofprotection:IP66front,IP20rear
Thetechnicalspecicationsarethosevalidforthecomputerthatmaybeorderedfrom
KongsbergMaritimeasapartoftheEA440delivery.Forspecicationsrelatedtoa
locallypurchasedcomputer,refertothedocumentationprovidedwiththeunit.
WBT
Makeandmodel:KongsbergWBT
Operationaltemperature:0to+50°C
Storagetemperature:-40to70°C
Relativehumidity:5to95%relative,non-condensing