147
7
© 2018 KOSTAL Solar Electric GmbH
General information
Log file: File header
The log file contains a file header with information on the
inverter:
Entry Explanation
Inverter number Number of the inverter (always 1)
Name Can be assigned by the user via the
browser
Current time The system time valid at the point in time
of file creation in seconds. This makes
allocation possible
(e.g. 1372170173 Unix time stamp =
25.06.2013 16:22:53)
Tab. 5: Log file file header
Log file: Physical variables
The file header is followed by the units of the physical
variables. The following table explains the abbreviations
for the physical variables:
Entry Explanation
U Voltage in volts [V]
I Current strength in milliamps [mA]
P Power in watts [W]
E Energy in kilowatt hours [kWh]
F Frequency in Hertz [Hz]
R Resistance in kiloohms [kOhm]
T Counting unit in points [digits]
Aln T Counting unit in points [digits]
Time Time in seconds [sec] since the inverter was put
into operation
TE Temperature in Celsius [°C]
H No function [%]
Tab. 6: Physical variables in the log file
INFO
Unix time stamp converter can be
found online.