Self-consumption
Activating active power control in the
Webserver
1. Connect inverter and computer. Ch. 5.1
2. Launch an Internet browser.
3. In the address line of the browser, enter the IP
address of the inverter to which the control box is
connected and confirm with "Return”.
P
The Webserver page is opened.
4. Log into the Webserver as an installer.
5. Go to “Service menu > Digital inputs”.
P
"Digital inputs" opens.
6. Select the function "Active power control".
7. Click on the "Save" button.
H
The active power control is enabled.
INFO
The IP address can be read on the
inverter’s display.