Maintenance
Activating self-consumption control
1. Calling up Webserver
2. Go to “Service menu > Switched output”
3. In the "Function" field, select the option "Self-
consumption control" or "Dynamic self-consumption
control".
4. Choose function 1 or function 2.
5. Enter values for the function.
6. Activate the optional value for "Leave switched
output activated in event of power loss or fault" using
check box and enter time period.
7. If there is a battery connected to the inverter, addi-
tional use for self-consumption can be activated
using the check box.
8. Click on “Save”.
H
The self-consumption control function is active.
INFO
When selecting "Dynamic self-con-
sumption control", the measured
home consumption determined using
the digital energy meter is automati-
cally added to the set value and taken
into consideration.
INFO
You can find more detailed expla-
nations regarding the selection of
function 1 or 2 in the course of the
chapter.
INFO
The command "Leave switched
output activated in event of power
loss or fault" can be used for function
1 and 2.
INFO
The command “Permit battery usage
for the switched output” is only
available if a battery is connected. If
this item is activated and there is no
PV energy, the power from the battery
is used for the consumers connected
to the self-consumption terminal until
the battery reaches the DoD.