Operation and operating the device
When working on the DC feed cables
When working on the DC feed cables, the inverter must
be completely de-energised.
It is absolutely essential that these steps are taken in
addition to those stated previously:
1. If present, switch o the connected battery
storage.
2. Disconnect all DC connections on the inverter. To do
this, unlock the engaging clips with a screwdriver and
disconnect the plug.
1
1.
2.
Fig. 40: Disconnecting SUNCLIX DC plug
3. Ensure that all connections are voltage-free.
H
The inverter is now completely voltage-free. Work
on the inverter or on the DC feed cables can now be
carried out.
DANGER
RISK OF DEATH DUE TO ELECTRI-
CAL SHOCK AND DISCHARGE!
De-energise all devices and secure
them against being switched on
again.
INFO
You will find a detailed description of
how to switch o the battery storage
in the operating manual provided by
the battery manufacturer.