16.15.2 Logical Alarms
Pos: 85.316 /BA /Info-Center/Gro ßpackenpresse /Hauptmenüs/Alar mmeldung en/2) Alarmmeld ungen Tab elle allgemein 0 - 9 @ 374\mo d_14425554913 88_78.docx @ 2 723075 @ @ 1
– The twine is torn.
– The twine end has been reached.
• Check the twine and the twine
tensioner.
– Blockage in the intake area of the
packer
– The "Packer monitoring" sensor
has been incorrectly set.
• Stop the travelling gear
immediately.
• Reduce the PTO speed until the
blockage has been removed.
• Correctly set the sensor.
– The force of pressure on the left
bale channel flap has been
exceeded.
In manual mode:
• Reduce the target bale channel
flap pressure.
In automatic mode:
• If the alarm is actuated
frequently, reduce the target
force of pressure.
– The force of pressure on the right
bale channel flap has been
exceeded.
– The knotter is not functioning
properly.
– The "Knotter monitoring" sensor
has been incorrectly set.
• Check the knotter and knotter
triggering.
• Correctly set the sensor.
– The "Measure" sensor is
defective or has been incorrectly
set.
• Correctly set the sensor.
– The "Calibrate" sensor is
defective or has been incorrectly
set.
• Correctly set the sensor.
– The flywheel brake is applied.
• Release the flywheel brake.
– The shear screw is torn.
• Replace the shear screw.
• Check the needles.
• Check the swivel range of the
needles.
• Check the twine guide.
– The bale chute is raised and the
PTO shaft is rotating.
• Lower the bale chute.