EasyManua.ls Logo

Krone Swadro TC 680 - Calibrating the Sensor - with Electrical Rotor Height Adjustment Design

Krone Swadro TC 680
138 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Settings
96
Pos: 36.12.1 /Überschr iften/Überschr iften 2/P-T/S/Sensor kalibrieren - bei Ausf ührung elektrisc he Kreiselhöhenverstel lung @ 359\mod_14391996979 12_78.docx @ 2661656 @ 2 @ 1
11.3 Calibrating the Sensor – with Electrical Rotor Height Adjustment Design
Pos: 36.12.2 /BA/Ei nstellungen/Schwader /Sensor kalibri eren - Einleitung @ 359\mod_14 39198670211_78.doc x @ 2662277 @ @ 1
The calibration only works if sensor voltage is less than 1 V (bottom stop) or greater than 4 V
(upper stop).
If this is not the case, consult KRONE specialist workshop so that the sensor can be readjusted
mechanically until the voltage values are again in the permissible range.
Park machine on level and firm ground so that both rotors are parallel to the ground.
Set the rotors to the least working height. In doing so, make sure that both rotors have the
same distance to the ground.
Due to allowed deviating tolerances of parts, the displays may contain different values before
calibration is performed.
Pos: 36.12.3 /BA/Ei nstellungen/Schwader /Sensor kalibri eren - Bild_Variante Plus _TC 760 @ 360\mod_1439371920 948_78.docx @ 2666547 @ @ 1
2
1
SW700097
Fig. 63
Pos: 36.12.4 /BA/Ei nstellungen/Schwader Sensor kalibrier en - Anzeigen nullen und Kalibr iervorgang @ 391\mod_1 445846105479_78.doc x @ 2799563 @ @ 1
Resetting the displays to zero
Lay permanent magnet on the display.
Calibration was successful when the display flashes three times.
If the display does not flash, perform calibration again.
Calibration process
Move each of the both rotors down to the ground.
Hold permanent magnet over the right display (1).
The right display flashes for approx. 5 seconds.
After that measurement value 0 is saved as lower limit of measuring range.
• Remove magnet.
Hold permanent magnet over the left display (2).
The left display flashes for approx. 5 seconds.
After that measurement value 0 is saved as lower limit of measuring range.
• Remove magnet.
Raise both rotors to headland position and raise rotor height adjustment until the stop is
reached.
Hold permanent magnet over the right display (1).
The right display flashes for approx. 5 seconds.
After that measurement value 99 is saved as upper limit of measuring range.
• Remove magnet.
Hold permanent magnet over the left display (2).
The left display flashes for approx. 5 seconds.
After that measurement value 99 is saved as upper limit of measuring range.
• Remove magnet.
Pos: 36.13 /Layout Module /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0. docx @ 4165 @ @ 1

Table of Contents

Related product manuals