EasyManua.ls Logo

Kuka KR AGILUS sixx - Stopping Distances and Stopping Times for STOP 1, Axis 3; Stopping Distances and Times, KR 10 R900 Sixx and KR 10 R1100 Sixx; Stopping Distances and Stopping Times for STOP 0, Axis 1 to Axis 3

Kuka KR AGILUS sixx
141 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
58 / 141 Issued: 28.03.2013 Version: MA KR AGILUS sixx V8 en (PDF)
KR AGILUS sixx
4.10.4.4 Stopping distances and stopping times for STOP 1, axis 3
4.10.5 Stopping distances and times, KR 10 R900 sixx and KR 10 R1100 sixx
The following values are preliminary values and are valid for the following ro-
bots.
KR 10 R900 sixx
KR 10 R900 sixx C
KR 10 R1100 sixx
KR 10 R1100 sixx C
4.10.5.1 Stopping distances and stopping times for STOP 0, axis 1 to axis 3
The table shows the stopping distances and stopping times after a STOP 0
(category 0 stop) is triggered. The values refer to the following configuration:
Extension l = 100%
Program override POV = 100%
Fig. 4-37: Stopping distances for STOP 1, axis 3
Fig. 4-38: Stopping times for STOP 1, axis 3

Table of Contents

Related product manuals