4.10.4.4 Stopping distances and stopping times for STOP 1, axis 3
4.10.5 Stopping distances and times, KR 10 R900 sixx and KR 10 R1100 sixx
The following values are preliminary values and are valid for the following ro-
bots.
KR 10 R900 sixx
KR 10 R900 sixx C
KR 10 R1100 sixx
KR 10 R1100 sixx C
4.10.5.1 Stopping distances and stopping times for STOP 0, axis 1 to axis 3
The table shows the stopping distances and stopping times after a STOP 0
(category 0 stop) is triggered. The values refer to the following configuration:
Extension l = 100%
Program override POV = 100%
Fig. 4-37: Stopping distances for STOP 1, axis 3