18. Carefully separate the Load Lifting Attachment from the bottom of the base
frame with the fork lift truck.
19. Fasten the robot to the wall with 2 M10x35 hexagon bolts and washers on
the bottom of the base frame.
Tighten the hexagon bolts alternately with torque wrench. Gradually in-
crease the tightening torque to 45 Nm.
20. Connect motor cable X30 and data cable X31 (>>> Fig. 8-9 ).
21. Connect the ground conductor between the robot controller and the robot
to the ground conductor connection.
22. Check the equipotential bonding in accordance with VDE 0100 and EN
60204-1.
23. Connect the ground conductor between the system component and the ro-
bot to the ground conductor connection.
24. Mount tooling, if present.
25. Retighten the 4 hexagon bolts with a torque wrench after 100 hours of op-
eration.
Put the robot system into operation in accordance with the “Start-up” chapter
of the operating and programming instructions for the KUKA System Software
(KSS) and the “Start-up” chapter of the operating instructions for the robot con-
troller.
8.5 Installing a ceiling-mounted robot
Description This description is valid for the installation of ceiling-mounted robots with the
mounting variant “Machine frame mounting”. For installation on the ceiling, the
robot must be fastened to the Load Lifting Attachment. The robot is fastened
Fig. 8-9: Connecting the cables
1 Ground conductor 3 Data cable
2 Motor cable
Further information is contained in the operating and assembly in-
structions of the robot controller.

Table of Contents