2H0/2HZ
2-4-8
When maintenance item U411 (Adjusting the scanner automatically) is run using the specified original (P/N 302FZ56990),
the following adjustments are automatically made:
Adjusting the scanner magnification (U065)
Adjusting the scanner leading edge registration (U066)
Adjusting the scanner center line (U067)
When maintenance item U411 (Adjusting the scanner automatically) is run using the specified original (P/N 2AC68241),
the following adjustments are automatically made:
Adjusting the DP magnification (U070)
Adjusting the DP scanning timing (U071)
Adjusting the DP center line (U072)
11
Adjusting the center line (scanning
adjustment)
Adjusting the original scan data
(image adjustment)
U067
U072
ADJUST DATA1/2
ADJUST DATA1/2
Test chart P.1-3-29
P.1-3-34
U067: For copying an original placed on
the platen.
U072: For copying originals from the DP.
12
Adjusting the leading edge registra-
tion (scanning adjustment)
Original scan start timing
(image adjustment)
U066
U071
ADJUST DATA1/2
ADJUST DATA1/2/
3/4
Test chart P.1-3-28
P.1-3-32
U066: For copying an original placed on
the platen.
U071: For copying originals from the DP.
13
Adjusting the leading edge margin
(scanning adjustment)
Adjusting the original scan data
(image adjustment)
U403
U404
B MARGIN
B MARGIN/
Test chart P.1-3-65
P.1-3-66
U403: For copying an original placed on
the platen.
U404: For copying originals from the DP.
14
Adjusting the trailing edge margin
(scanning adjustment)
Adjusting the original scan data
(image adjustment)
U403
U404
D MARGIN
D MARGIN/
Test chart P.1-3-65
P.1-3-66
U403: For copying an original placed on
the platen.
U404: For copying originals from the DP.
15
Adjusting the left and right margins
(scanning adjustment)
Adjusting the original scan data
(image adjustment)
U403
U404
A MARGIN
C MARGIN
A MARGIN/
C MARGIN/
Test chart P.1-3-65
P.1-3-66
U403: For copying an original placed on
the platen.
U404: For copying originals from the DP.
Adjusting
order
Item Image Description
Maintenance mode
Original Page Remarks
Item No. Mode
Image quality
Item
Specifications
100% magnification
Enlargement/reduction
Lateral squareness
Leading edge registration
Skewed paper feed
Left-right difference
Curling
Machine: ±0.8%
Using DP: ±1.5%
Machine: ±1.0%
Using DP: ±1.5%
Machine: ±1.5 mm/375 mm
Using DP: ±3.0 mm/375 mm
Cassette: ±2.5 mm
MP tray: ±2.5 mm
Duplex mode: ±2.5 mm
Cassette: 1.5 mm or less
MP tray: 1.5 mm or less
Duplex mode: 2.0 mm or less
Cassette: 2.0 mm or less
MP tray: 2.0 mm or less
Duplex mode: 3.0 mm or less
Simplex mode: 10.0 mm or less
Duplex mode: 10.0 mm or less