SMNT
315
COLOR
SMNT — Set MoNiTor simulation
Format
SMNT monitor-type [,temperature, red-x, red-y, green-x, green-y, blue-x, blue-y,
gamma];
Parameters
monitor-type:
0 = None
1 = SMPTE 240M
2 = HDTV (sRGB) [default]
3 = Sony Trinitron
4 = Apple RGB
5 = NTSC
6 = KC-RGB
7 = Custom
temperature:
color temperature
3500, 5000, 5500, 6500 (default), 6740, 7500, 9300
red-x/red-y/...
chromaticity coordinates:
red-x: number from 0.0 to 3.0 (default = 0.64)
red-y: number from 0.0 to 3.0 (default = 0.33)
green-x: number from 0.0 to 3.0 (default = 0.30)
green-y: number from 0.0 to 3.0 (default = 0.60)
blue-x: number from 0.0 to 3.0 (default = 0.15)
blue-y: number from 0.0 to 3.0 (default = 0.06)
gamma
value of gamma correction:
number from 1.0 to 3.0 (default = 2.2)
Function
The SMNT command simulates a particular monitor or a monitor customized by
specifying the color temperature, etc. Parameters except monitor-name are enabled only
when monitor-name value is 7 (custom).
Resetting the printing system or switching emulation modes resets all custom parameters
to the default states.
The simulation provided by this command is enabled only when the device-dependent
color space is in use.

Table of Contents

Other manuals for Kyocera KM-C3232E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kyocera KM-C3232E and is the answer not in the manual?

Kyocera KM-C3232E Specifications

General IconGeneral
BrandKyocera
ModelKM-C3232E
CategoryPrinter Accessories
LanguageEnglish

Related product manuals