EasyManuals Logo

Lab.gruppen PLM Series User Manual

Lab.gruppen PLM Series
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
44
Front Panel Interface
PLM Series Operation Manual rev 1.1.9
AMP indicates the current actual temperature of that channel’s power output stage as a percentage of
its maximum permitted value. The numerical value is in dB relative to signal clip.
The computed temperature of voice coil (VC) of the loudspeaker connected to that output channel. This
parameter is calculated using the power currently being dissipated in the load, and by using the loud-
speaker data from the LoadLibrary Fingerprint as presented by the SpeakerSafe output. The numerical
value is displayed in degrees Celsius.
The computed temperature of the magnet (MAG) of the loudspeaker connected to the output channel.
This parameter is calculated and displayed in a similar way to the voice coil (VC) temperature.
7.10.4 Input View
Input View enables inspection of the input signal before the input mixer (i.e. prior to the Home View Module
input meters).
Figure 7-7: Meter Mode > Input View
Current View title & Frame label, Frame faults and warnings
Input Router 1: Selected input type, input gain level (relative to clip), router fault/warning/clip
Input Router 2: Selected input type, input gain level (relative to clip), router fault/warning/clip
AES/EBU Terminated & Iso-Float Grounded icons (no icons = AES Unterminated / Iso-Float Floating)
Unused in Input View
Module A Input Mixer: Input 1/2 Connection Status, Module A input level meter
Module B Input Mixer: Input 1/2 Connection Status, Module A input level meter
Combined channel status summarizing faults and warnings for all power outputs

Table of Contents

Other manuals for Lab.gruppen PLM Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lab.gruppen PLM Series and is the answer not in the manual?

Lab.gruppen PLM Series Specifications

General IconGeneral
DSPYes
NetworkEthernet
ConnectorsXLR, SpeakON
CoolingForced air
Protection FeaturesOverheat, DC, short circuit
Control SoftwareLake Controller

Related product manuals