3. INSTALLATION
17
ADDITIONAL REMARKFITTING THE EXTENSION TABLE
1. Fasten the extension table and keep it aligned with cast iron table. Check the
flatness use a flat straight gauge or the alum. Rip fence which go with rip fence
( Figure 3-5.7) on the tables as Fig 3-5.12. The extension table must be even
height to cast iron table. However, if the extension table is lower, the distance
must be less than 0.2mm for smooth operation.
2. If it is not aligned, screw down the three screw A(Fig. 3-5.13)
3. Then adjust the alignment with screws B(Fig. 3-5.13)
All fitting operations in this section require approx. 2 people
A
B