Connect your RJ-45 Ethernet cable to the RJ-45 port of the unit.
The xSenso supports a power range of 9 to 30 VDC. You can power up the device with barrel-
power connector and/or the 3 pin terminal connector for backup power supply.
Note: As soon as you plug the device into power, the device/sensors powers up
automatically, the self-test begins, and LEDs would indicate the device's status
Perform the following steps to install your device:
1. Connect analog xSenso to the analog input ports.
2. Hook up power excitations from xSenso to analog sensors/devices if needed and if xSenso
meets the power requirement.
3. Connect a RJ-45 Ethernet cable between the unit and your Ethernet network.
4. Connect the 9-30 VDC to the terminal block, barrel jack or both, and power on the xSenso.
5. Power up analog input devices/sensors if they are not powered by xSenso excitation.