The Network Data Repeater (P/No. ZXT340) can be connected
into the Advent xt RS485 network to boost the data signal
on cable runs over 1200 metres.
POWER IN ➔
RS485 DATA IN ➔
RS485 DATA OUT
INSTALLATION
The Network Data Repeater is housed in a wall mounted ABS enclosure; 85 x 170 x 35 mm (HxWxD).
TERMINATION
The 24V & 0V power connection can be taken from the Advent xt network.
Cut the Advent xt network data wires (TX+/TX-) at a point before the signal begins to fail.
Connect TX+/TX- FROM the Advent xt controller into the RS485 IN terminals
Connect the remaining Advent xt network data wires TX+/TX- into the RS485 OUT terminals.
LINK SETTINGS
LK1-LK4 will normally be fitted in position “A”. Only move if advised by Tynetec Technical Support.
DIL SWITCH SETTINGS
SW1 allows a different end of line (EOL) resistance to be set on the RS485 IN terminals depending on the number of
network legs connected to the Advent xt controller.
SW2 allows a different end of line (EOL) resistance to be set on the RS485 OUT terminals. This is normally left open
circuit. Only move if advised by Tynetec Technical Support.