Doc No. FM0410 issue N Page 1
Advent XT
Assisted Living Call Management System
_________________________________________________________________________________________________________________
Installation Manual
Tynetec operates a policy of continual product improvement and
Reserves the right to modify the specification of its products.
If any variation to the details in this document are suspected please
contact Tynetec’s Technical Support on 01670 352371.
Tynetec, a business unit of Legrand Electric Ltd
Cowley Road, Blyth Riverside Business Park, Blyth, Northumberland, NE24 5TF.
T: +44 (0) 1670 352 371 www.tynetec.co.uk
_______________________________________________________________________________________________________________
Trusted Technology
Caring for People

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the LEGRAND tynetec Advent XT and is the answer not in the manual?

LEGRAND tynetec Advent XT Specifications

General IconGeneral
BrandLEGRAND
Modeltynetec Advent XT
CategorySecurity System
LanguageEnglish

Summary

Safety Instructions

Regulatory Information

Maintenance & Care

Related Documentation

Introduction

System Overview

Wiring Requirements

Details on system wiring for Advent XT, including cable types and network limits.

System Programming

Requirements for system programming using a laptop and specific software.

Controller Installation

Installation and Mounting

Location and mounting guidelines for the Advent XT controller enclosure.

Mains Supply Connection

Connecting the 240V AC mains supply to the controller via a fused spur.

Controller Installation (Continued)

27V SMPSU Module

Details on the 27V/150W switched mode power supply unit within the controller.

Battery Standby

Information on the 12V rechargeable batteries for system standby power.

Telephone Connection

Connecting external telephone lines and DECT base stations to the controller.

Network Wiring

Network Wiring Guidelines

Describes cable requirements, network length limits, and device limits for the Advent XT system.

Wiring Configurations

Illustrates correct and incorrect network wiring layouts and spur connections.

Network Load Considerations

Voltage Drop Calculation

Explains how to calculate voltage drop and provides an example for the Advent XT network.

Reducing Voltage Drop

Lists methods to reduce voltage drop in the network, such as splitting runs or using thicker cables.

Network Termination Board

RS232 Ports

Details the use of RS232 ports for PC connection and network device programming.

Link Settings

Explains link settings for configuring RS232 ports for monitoring or programming.

Inputs

Describes the 4 inputs available for activation via clean contacts, including fire alarm tone.

Network Termination Board (Continued)

Fire Alarm Input

Details how the fire alarm input triggers calls and fire tones, with different firmware versions.

External PSU Input

Information on using external power supplies for increased network current requirements.

Fuses

Details the fuse protection for 12V and 24V DC supplies on network connections.

Network Termination Board (Continued)

PA & Door Entry Terminals

Terminal functions for connecting PA amplifiers and door entry panels.

System Network Terminals

Describes the pluggable XT network terminals and their functions.

Ferrite Core Usage

Explains the purpose and use of ferrite cores to suppress voltage transients.

Network Cable Colour Code

CW1308 Network Cable Colour Code

Recommended colour code for CW1308 cable, detailing pairs, diameter, colour, and signal.

Tunstall Network Cable Colour Code

Colour code for using existing Tunstall Telecom cable with the Advent XT system.

Network Cable Limitations

Lists limitations of network cable length and potential issues like voltage drop and data corruption.

PA Amplifier Installation

Installation and Mounting

Instructions for housing and mounting the PA amplifier and SMPSU enclosure.

Mains Supply Connection

Connecting the 240V AC mains supply to the PA amplifier and SMPSU.

Wiring Termination

Details cable connections from the PA amplifier to the Advent XT termination board.

Intercom Unit Installation

Intercom Unit Mounting

Steps for wall mounting the intercom unit, ensuring correct fixing and orientation.

Intercom Termination

Explains how to terminate network wiring on the intercom's interconnect board.

Intercom Unit Auxiliary Devices

Ceiling Pullcords (Normally Open)

Connecting normally open ceiling pullcords to the intercom unit.

Ceiling Pullcords (Normally Closed)

Connecting normally closed ceiling pullcords, including firmware and DIL switch settings.

Smoke/Heat Detectors

Information on connecting smoke/heat detectors with N/O clean contacts to the intercom.

Intercom Unit Auxiliary Devices (Continued)

PIR Detectors

Connecting PIR detectors, noting their power source and contact type.

Additional Inputs

Details on wiring four additional inputs to intercom terminals for various sensors.

Strobe Light Connection

Information on connecting the Advent XT strobe light, including DIL switch settings.

Intercom Unit DIL Switches & Link Settings

Intercom Address DIL Switch

How to set the 8-bit binary address for intercom units sequentially on the site.

Intercom Options DIL Switch

Enabling auxiliary equipment like door entry or PIRs using the Options DIL switch.

Intercom Links Settings

Explains link settings (LK1-LK3) for selecting intercom mode (master/remote/standard).

Remote Intercom Unit Installation

Remote Intercom Installation

Connecting a remote intercom to a standard intercom, including cable length and limits.

DIL Switch and Link Settings

Setting DIL switches and links to identify a master or remote intercom.

Remote Intercom Operation

How to use the master and remote intercoms, including call initiation and LED indicators.

Fitting & Removing the Intercom Front

Fitting the Intercom Front

Step-by-step guide on how to attach the intercom front cover after setup.

Removing the Intercom Front

Instructions on how to safely remove the intercom front cover.

Intercom Unit Test Mode

Entering Test Mode

Procedure to enter the intercom's test mode for input device testing.

Alarm Button Glow Off

How to disable the dim red standby glow of the alarm button.

Exiting Test Mode

How to exit the intercom unit's test mode.

Manager Callpoint Installation

Installation and Mounting

Mounting and installation details for the Manager Callpoint, including backbox options.

Wiring Termination

Connecting the Manager Callpoint to the system network wiring.

DIL Switches & Links Configuration

Setting DIL switches and links for the Manager Callpoint address and options.

Door Lock Connection

Connecting a door lock release to the Manager Callpoint using an auxiliary PSU.

Lift Callpoint Installation

Installation and Retrofitting

Details for retrofitting the Lift Callpoint, including cut-out dimensions.

Interface Unit Termination

Connecting the Lift Callpoint interface unit to the Advent XT network.

Surface Mount Option

Information on the surface mount ABS intercom case version of the Lift Callpoint.

Status Module Installation

Network Connection

Connecting the Status Module to the system network wiring for power and data.

Printer Option Setup

Connecting an Advent XT printer to the Status Module to record system activity.

Manager's Display Panel Installation

Power Supply Connection

Connecting the Manager's Display Panel to its battery-backed 12V/2A DC PSU.

RS485 Data Connection

Connecting the Manager's Display Panel data cable to the Advent XT controller.

169MHz Network Receiver Installation

Receiver Connection

Connecting Network Receivers to the Advent XT system network using CW1308 cable.

Link Settings & Software Versions

Details on link settings (LK1/LK2) and firmware versions for Network Receivers.

Receiver Installation Location

Site selection criteria for Network Receivers to ensure optimal radio coverage.

169MHz Network Receiver Installation (Continued)

169MHz Separation Guidelines

Minimum separation distances required between Network Receivers, aerials, and other devices.

Aerial Connection

Connecting the 169MHz aerial to the Network Receiver using the provided cable.

ID Setting for Receivers

Setting unique IDs for Network Receivers using DIL switches 1 to 4.

Zoned Network Receiver Installation

Attenuator & Aerial Setup

Details on fitting the attenuator and helical stub aerial for Zoned Network Receivers.

Receiver Connection

Connecting Zoned Network Receivers to the Advent XT system network.

Zoned Receiver Installation Location

Site selection guidelines for Zoned Network Receivers to cover specific zones.

ID Setting for Zoned Receivers

Setting unique IDs for Zoned Network Receivers using DIL switches.

Zoned Network Receiver Installation (Continued)

Enable RSSI Print-Out

How to enable the printing of RSSI values for Zoned Network Receivers.

Testing Zoned Receivers

Performing walk tests to check radio coverage and RSSI values for Zoned Network Receivers.

Attenuating RSSI Values

Procedure to adjust RSSI values for optimal coverage and minimal overlap.

Resetting All Zones to Full RSSI

How to reset all Zoned Network Receivers to full strength attenuation.

Digital Door Panel Installation

Digital Door Panels Overview

Details on connecting up to 16 digital door panels to the Advent XT controller.

Door Panel Installation

Mounting guidelines for the digital door panel backbox and fascia.

Ferrite Core Usage

Instructions on using a ferrite core for the door panel wiring to suppress transients.

Digital Door Panel Installation (Continued)

Door Panel Termination Wiring

Wiring connections for the door panel amplifier board, including terminals and functions.

Link Settings Configuration

Setting link options for lock type, expander fitting, and expander type.

8-Way DIL Switch Settings (SW2)

Configuring door panel ID and features using the 8-way DIL switch.

Digital Door Panel Installation (Continued)

Door Panel Programming

Programming door panel features like access codes, trade times, and call transfer.

Volume and Audio Adjustment

Adjusting audio levels and VOX sensitivity for door entry and warden call.

Lock Connection and Configuration

Connecting the electric lock release to the door panel and its requirements.

Door Entry Telephone Installation

Telephone Installation

Wall mounting the door entry telephone and ensuring correct fitting.

Telephone Termination

Wiring the door entry telephone to the Advent XT intercom unit.

Door Entry Telephone Installation (Continued)

Telephone Termination Wiring Details

Detailed table of intercom and telephone terminal connections and wire colours.

Dual Handset Configuration

Connecting a second handset to a dwelling, including link settings and limitations.

Telephone Link Settings

Setting telephone link positions (LK1, LK2, LK3) for master/slave configurations.

Combined Intercom Installation

Combined Intercom Installation

Wall mounting the combined intercom unit, ensuring correct fixing and orientation.

Combined Intercom Termination

Terminating network wiring on the combined intercom's interconnect board.

Combined Intercom Installation (Continued)

Combined Intercom Address DIL Switch

Setting the 8-bit binary address for combined intercoms sequentially on the site.

Combined Intercom Options DIL Switch

Enabling auxiliary equipment connected to the combined intercom via the Options DIL switch.

Combined Intercom Link Options

Explains link settings (LK1/LK2) for standard or remote intercom configurations.

Combined Intercom Installation (Continued)

Strobes and Volume Control

Connecting strobes and adjusting volume for combined intercoms.

Button Functions and LED Colours

Explains the functions of buttons and the meaning of LED colours/patterns on the intercom.

Privacy Mode Operation

How to select and use privacy mode on the combined intercom, including auto-reset settings.

BLE Remote Control Installation

BLE Remote Control Address DIL Switch

Setting the 8-way DIL switch on the BLE Remote Control to match the intercom address.

Learning the BLE Remote Control

Step-by-step process to pair and learn the BLE Remote Control with the intercom.

Deleting the BLE Remote Control

Procedure to remove a paired BLE Remote Control from the intercom.

Door Open Alarm Installation

Door Open Alarm Installation

Mounting the Door Open Alarm unit near the monitored door.

Door Open Alarm Termination

Connecting the Door Open Alarm to a door contact and an Advent XT intercom.

Intercom Settings for Door Open Alarm

Configuring the connected intercom for intruder mode and door open alarm functions.

BT Line Selector Installation

BT Line Selector Termination

Connecting the BT Line Selector to the Advent XT controller and BT lines.

BT Line Selector Programming

Programming the BT Line Selector for secondary line and GSM terminal usage.

GSM Cellular Terminal Connection

Connecting and setting up the optional GSM Cellular Terminal with the BT Line Selector.

Network Data Repeater Installation

Repeater Installation

Housing and mounting the Network Data Repeater enclosure.

Repeater Termination

Connecting the Network Data Repeater to the Advent XT network for data signal boosting.

Repeater Link Settings

Explains link settings (LK1-LK4) for configuring the Network Data Repeater.

Repeater DIL Switch Settings

Setting DIL switches (SW1, SW2) for end-of-line resistance on RS485 terminals.

Ethernet Interface Kit Installation

Local/Remote Connection

Connecting the Ethernet Interface Kit to a local PC or remotely via broadband.

Ethernet Interface Kit Installation

Fitting the Ethernet Interface Kit to the Advent XT controller.

Ethernet Interface Kit Installation (Continued)

Expander Board LED Indicators

Explains the function of each LED indicator on the expander board.

Expander Board DIL Switches

Details the DIL switches on the expander board, including IP address reset.

Digital Communicator Installation

Digital Communicator Installation

Housing and mounting the Digital Communicator enclosure.

Digital Communicator Termination

Connecting the Digital Communicator to the controller, router, and power sources.

Digital Communicator Installation (Continued)

Ethernet Connection Setup

Setting up the Ethernet connection for the Digital Communicator to a digital ARC.

Controller Firmware Level Report

Controller Firmware Level Report

Procedure to check and report the firmware versions of the Advent XT controller.

Specification - Controller

Specification - PA Amplifier

Specification - Intercom

Specification - BLE Remote Control

Specification - Managers Callpoint

Specification - Lift Callpoint (Flush Stainless Steel)

Specification - Lift Callpoint (Surface ABS)

Specification - 169MHz Network Receiver

Specification - Manager's Display Panel

Specification - Door Entry Panel

Specification - Door Entry Telephone

Specification - Line Selector

Specification - Data Repeater

Specification - Door Open Alarm

Specification - Master Strobe

Specification - Slave Strobe

Amendments Record

Related product manuals