Details on system wiring for Advent XT, including cable types and network limits.
Requirements for system programming using a laptop and specific software.
Location and mounting guidelines for the Advent XT controller enclosure.
Connecting the 240V AC mains supply to the controller via a fused spur.
Details on the 27V/150W switched mode power supply unit within the controller.
Information on the 12V rechargeable batteries for system standby power.
Connecting external telephone lines and DECT base stations to the controller.
Describes cable requirements, network length limits, and device limits for the Advent XT system.
Illustrates correct and incorrect network wiring layouts and spur connections.
Explains how to calculate voltage drop and provides an example for the Advent XT network.
Lists methods to reduce voltage drop in the network, such as splitting runs or using thicker cables.
Details the use of RS232 ports for PC connection and network device programming.
Explains link settings for configuring RS232 ports for monitoring or programming.
Describes the 4 inputs available for activation via clean contacts, including fire alarm tone.
Details how the fire alarm input triggers calls and fire tones, with different firmware versions.
Information on using external power supplies for increased network current requirements.
Details the fuse protection for 12V and 24V DC supplies on network connections.
Terminal functions for connecting PA amplifiers and door entry panels.
Describes the pluggable XT network terminals and their functions.
Explains the purpose and use of ferrite cores to suppress voltage transients.
Recommended colour code for CW1308 cable, detailing pairs, diameter, colour, and signal.
Colour code for using existing Tunstall Telecom cable with the Advent XT system.
Lists limitations of network cable length and potential issues like voltage drop and data corruption.
Instructions for housing and mounting the PA amplifier and SMPSU enclosure.
Connecting the 240V AC mains supply to the PA amplifier and SMPSU.
Details cable connections from the PA amplifier to the Advent XT termination board.
Steps for wall mounting the intercom unit, ensuring correct fixing and orientation.
Explains how to terminate network wiring on the intercom's interconnect board.
Connecting normally open ceiling pullcords to the intercom unit.
Connecting normally closed ceiling pullcords, including firmware and DIL switch settings.
Information on connecting smoke/heat detectors with N/O clean contacts to the intercom.
Connecting PIR detectors, noting their power source and contact type.
Details on wiring four additional inputs to intercom terminals for various sensors.
Information on connecting the Advent XT strobe light, including DIL switch settings.
How to set the 8-bit binary address for intercom units sequentially on the site.
Enabling auxiliary equipment like door entry or PIRs using the Options DIL switch.
Explains link settings (LK1-LK3) for selecting intercom mode (master/remote/standard).
Connecting a remote intercom to a standard intercom, including cable length and limits.
Setting DIL switches and links to identify a master or remote intercom.
How to use the master and remote intercoms, including call initiation and LED indicators.
Step-by-step guide on how to attach the intercom front cover after setup.
Instructions on how to safely remove the intercom front cover.
Procedure to enter the intercom's test mode for input device testing.
How to disable the dim red standby glow of the alarm button.
How to exit the intercom unit's test mode.
Mounting and installation details for the Manager Callpoint, including backbox options.
Connecting the Manager Callpoint to the system network wiring.
Setting DIL switches and links for the Manager Callpoint address and options.
Connecting a door lock release to the Manager Callpoint using an auxiliary PSU.
Details for retrofitting the Lift Callpoint, including cut-out dimensions.
Connecting the Lift Callpoint interface unit to the Advent XT network.
Information on the surface mount ABS intercom case version of the Lift Callpoint.
Connecting the Status Module to the system network wiring for power and data.
Connecting an Advent XT printer to the Status Module to record system activity.
Connecting the Manager's Display Panel to its battery-backed 12V/2A DC PSU.
Connecting the Manager's Display Panel data cable to the Advent XT controller.
Connecting Network Receivers to the Advent XT system network using CW1308 cable.
Details on link settings (LK1/LK2) and firmware versions for Network Receivers.
Site selection criteria for Network Receivers to ensure optimal radio coverage.
Minimum separation distances required between Network Receivers, aerials, and other devices.
Connecting the 169MHz aerial to the Network Receiver using the provided cable.
Setting unique IDs for Network Receivers using DIL switches 1 to 4.
Details on fitting the attenuator and helical stub aerial for Zoned Network Receivers.
Connecting Zoned Network Receivers to the Advent XT system network.
Site selection guidelines for Zoned Network Receivers to cover specific zones.
Setting unique IDs for Zoned Network Receivers using DIL switches.
How to enable the printing of RSSI values for Zoned Network Receivers.
Performing walk tests to check radio coverage and RSSI values for Zoned Network Receivers.
Procedure to adjust RSSI values for optimal coverage and minimal overlap.
How to reset all Zoned Network Receivers to full strength attenuation.
Details on connecting up to 16 digital door panels to the Advent XT controller.
Mounting guidelines for the digital door panel backbox and fascia.
Instructions on using a ferrite core for the door panel wiring to suppress transients.
Wiring connections for the door panel amplifier board, including terminals and functions.
Setting link options for lock type, expander fitting, and expander type.
Configuring door panel ID and features using the 8-way DIL switch.
Programming door panel features like access codes, trade times, and call transfer.
Adjusting audio levels and VOX sensitivity for door entry and warden call.
Connecting the electric lock release to the door panel and its requirements.
Wall mounting the door entry telephone and ensuring correct fitting.
Wiring the door entry telephone to the Advent XT intercom unit.
Detailed table of intercom and telephone terminal connections and wire colours.
Connecting a second handset to a dwelling, including link settings and limitations.
Setting telephone link positions (LK1, LK2, LK3) for master/slave configurations.
Wall mounting the combined intercom unit, ensuring correct fixing and orientation.
Terminating network wiring on the combined intercom's interconnect board.
Setting the 8-bit binary address for combined intercoms sequentially on the site.
Enabling auxiliary equipment connected to the combined intercom via the Options DIL switch.
Explains link settings (LK1/LK2) for standard or remote intercom configurations.
Connecting strobes and adjusting volume for combined intercoms.
Explains the functions of buttons and the meaning of LED colours/patterns on the intercom.
How to select and use privacy mode on the combined intercom, including auto-reset settings.
Setting the 8-way DIL switch on the BLE Remote Control to match the intercom address.
Step-by-step process to pair and learn the BLE Remote Control with the intercom.
Procedure to remove a paired BLE Remote Control from the intercom.
Mounting the Door Open Alarm unit near the monitored door.
Connecting the Door Open Alarm to a door contact and an Advent XT intercom.
Configuring the connected intercom for intruder mode and door open alarm functions.
Connecting the BT Line Selector to the Advent XT controller and BT lines.
Programming the BT Line Selector for secondary line and GSM terminal usage.
Connecting and setting up the optional GSM Cellular Terminal with the BT Line Selector.
Housing and mounting the Network Data Repeater enclosure.
Connecting the Network Data Repeater to the Advent XT network for data signal boosting.
Explains link settings (LK1-LK4) for configuring the Network Data Repeater.
Setting DIL switches (SW1, SW2) for end-of-line resistance on RS485 terminals.
Connecting the Ethernet Interface Kit to a local PC or remotely via broadband.
Fitting the Ethernet Interface Kit to the Advent XT controller.
Explains the function of each LED indicator on the expander board.
Details the DIL switches on the expander board, including IP address reset.
Housing and mounting the Digital Communicator enclosure.
Connecting the Digital Communicator to the controller, router, and power sources.
Setting up the Ethernet connection for the Digital Communicator to a digital ARC.
Procedure to check and report the firmware versions of the Advent XT controller.