7-2 Test and Adjustment
12. Examine if the calibrated values are in the range between 280 - 315 mm (11 - 13 in). If not, do the
calibration again.
7.3 Set the Gyroscope Target Temperature
Only change this setting if the gyroscope does not calibrate properly.
On the smartphone:
1. Connect your smartphone to the machine.
2. In the main menu tap Settings.
3. Tap Gyroscope.
The applicable target temperature of the gyroscope is about 15 degrees higher than
the average maximum outside temperature for that period.
4. Tap the temperature.
5. Tap OK to set the selected target temperature.