EasyManua.ls Logo

LEMKEN Ecospray - 14 Rectifying Faults; General; Deactivating Warnings, Malfunctions or Notes

LEMKEN Ecospray
141 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rectifying faults
131
14 RECTIFYING FAULTS
14.1 General
As a rule, alarms, warnings or notes are made brought to your attention as follows:
Acoustic signal sounds
Error message shown in display
Light-emitting diode flashes red
Alarms, warnings or notes can be displayed in the following categories:
Category Alarm/Warning/Note
A Warnings/faults/notes
B Open circuits
C Short circuits
D System errors
Warnings, faults or notes can be confirmed as follows:
- Press the rotary encoder in order to confirm the alarm, warning or note.
14.1.1 Deactivating warnings, malfunctions or notes
Warnings, malfunctions or notes can be deactivated as follows:
14.1.1.1 Category A
- Press a function key for roughly 2 seconds to deactivate the alarm, warning or note.
14.1.1.2 Category B - D
- Press the key to deactivate the alarm, warning or note.
If the terminal is restarted, the deactivated warnings, malfunctions or notes are automatically
shown again
As soon as the fault is rectified, the red light-emitting diode goes out.

Table of Contents