Rectifying faults
136
14.5 D - System faults
Code Description Possible cause Corrective measure
D01 CAN-BUS fault
Missing terminal plug
Deficient bus line
Defective connector job computer
Defective connector terminal
Visual inspection
Replace cable, where necessary
Replace job computer, where nec-
essary
Replace terminal, where necessary
D02
LIN-BUS 1 fault (job
computer)
Deficient bus line
Defective connector job computer
Defective connector LIN supplemental
device
Visual inspection
Replace cable, where necessary
Replace connector, where neces-
sary
Replace supplemental operating
device, where necessary
D03
LIN-BUS 2 fault
(terminal)
Deficient bus line
Defective connector terminal
Defective connector LIN supplemental
device
Visual inspection
Replace cable, where necessary
Replace connector, where neces-
sary
Replace supplemental operating
device, where necessary
D04
Emergency-stop
chain interrupted
Missing terminal plug
Deficient bus line
Defective connector job computer
Defective connector terminal
Visual inspection
Replace cable, where necessary
Replace connector, where neces-
sary
D05 Undervoltage fault Wrong or defective voltage supply Check voltage supply
D06 Overvoltage fault Wrong or defective voltage supply Check voltage supply
D07
Job computer tem-
perature fault
Overheating Find cause for high temperature