Extending and retracting HE linkage
61
10.11 Emergency circuit
WARNING
This function should only be operated if:
the linkage is outside the monitoring range of the arm bending [SE link-
age only]
there is a malfunction of the sensors on the linkage.
The sensors must then be checked or other folding functions will have to the
performed previously in order to perform the desired function.
To fold-in or extend the linkage in the event of a sensor fault, the control unit can be operated
with an emergency circuit.
The emergency circuit operates when a Folding menu was selected.
- Press the key and hold it down.
The Folding menu and the warning notes display appear alter-
nately.
To preselect the folding function when the Folding menu appears:
- Press one of the keys.
The light-emitting diode on the key lights up.
- Hold the key down.
To extend the linkage:
- Operate the tractor's corresponding control unit.