Rectifying faults
133
14.3 B - Line breaks
These differ depending on the device version.
Code Output Description Possible cause Corrective measure
B01 SA1 Y2 boom 4 left
Cable connection defi-
cient
Visual inspection
Replace cable, whe-
re necessary
B02 SA2 Y4 valve boom 3 left
Cable connection defi-
cient
Visual inspection
Replace cable, whe-
re necessary
B03 SA3 Y6 valve boom 2 left
Cable connection defi-
cient
Visual inspection
Replace cable, whe-
re necessary
B04 SA4 Y8 valve boom 1 left
Cable connection defi-
cient
Visual inspection
Replace cable, whe-
re necessary
B05 SA5 Y10 valve boom 1 right
Cable connection defi-
cient
Visual inspection
Replace cable, whe-
re necessary
B06 SA6 Y12 valve boom 2 right
Cable connection defi-
cient
Visual inspection
Replace cable, whe-
re necessary
B07 PA1 Y14 valve boom 3 right
Cable connection defi-
cient
Visual inspection
Replace cable, whe-
re necessary
B08 PA2 Y16 valve boom 4 right
Cable connection defi-
cient
Visual inspection
Replace cable, whe-
re necessary
B09 PA3 Y18/Y19 valve pendulum lock
Cable connection defi-
cient
Visual inspection
Replace cable, whe-
re necessary
B10 PA4
Y20/21 valve slope compensa-
tion
Cable connection defi-
cient
Visual inspection
Replace cable, whe-
re necessary
B11 PB1 Y22 oil flow 4/3 lines
Cable connection defi-
cient
Visual inspection
Replace cable, whe-
re necessary
B12 PB2 Y23 oil flow 3/3 lines
Cable connection defi-
cient
Visual inspection
Replace cable, whe-
re necessary
B13 PB3 Y24 oil flow valve lifting mast
Cable connection defi-
cient
Visual inspection
Replace cable, whe-
re necessary
B14 PB4 free
Cable connection defi-
cient
Visual inspection
Replace cable, whe-
re necessary