Procedure
Step 1. Open the retention latch.
Step 2. If a filler has been installed in the PCIe slot, remove the screw that secures it, and remove the filler.
Step 3. Align the adapter with the connector on the system board, and push it in.
Figure 79. Installing an adapter to the system board
Step 4. Secure the adapter with a screw.
Step 5. Close the retention latch.
Install an adapter in the PCIe riser assembly
Watch the procedure. A video of this procedure is available from the following links:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-C6QgmsUMRG6ul0bHzrGmsG
https://list.youku.com/albumlist/show/id_54461099
Procedure
Step 1. Open the retaining bracket on the PCIe riser assembly.
Step 2. If a filler has been installed to the slot on the riser, remove the screw that secures it and remove the
filler.
Step 3. Align the adapter with the connector on the PCIe riser assembly, and push it in.
Chapter 5. Server hardware setup 187