V100S
PCIe switch adapters
Step 1. See the following table to determine the proper slot and riser cage for the adapter to be installed.
Table 39. Supported PCIe adapters and corresponding riser cage and slots
x16/x16 riser cage x8/x8/x8/x8 riser cage
PCIe Slot
2 4 10 12
1/9 2/10 3/11 4/12
Nvidia Tesla V100s
Nvidia Tesla T4
1610-8p NVMe switch
adapter
Attention: When one unit of Nvidia Tesla V100s is installed in a x16/x16 Riser cage, do no installed
any adapter in the other slot.
Step 2. Install the adapter into the 4U PCIe riser cage.
Figure 115. Installing the adapter into the 4U PCIe riser cage
Connect the power auxiliary cable.
Insert the adapter into the connector in the riser cage.
Close both the retaining latches to secure the adapter.
Step 3. (Optional) Secure the adapter with one of the four spare screws that come with the 4U PCIe riser
cage.
Chapter 5. Server hardware setup 219