Whenyourestarttheserver,youarepromptedtoimporttheexistingRAIDconfigurationtothenew
ServeRAIDSAS/SATAcontroller.
RemovingaServeRAIDSAS/SATAcontrollermemorymodule
Note:Forbrevity,inthisdocumentationtheLenovoServeRAIDSAS/SATAcontrollerisoftenreferredtoas
theSAS/SATAadapterortheServeRAIDadapter.
ToremoveaServeRAIDadaptermemorymodule,dothefollowing:
Step1.Turnofftheserver.Then,disconnectallexternalcablesandremoveallperipheraldevices.
Step2.Removetheservercover.See“Removingtheservercover”onpage88.
Step3.RemovethePCIriser-cardassembly.See“RemovingthePCIriser-cardassembly”onpage93.
Step4.RemovetheServeRAIDadapter.See“Removinganadapter”onpage110.
Step5.GraspthememorymoduleandlifttoremoveitfromtheServeRAIDadapter.
Figure45.ServeRAIDadaptermemorymoduleremoval
Step6.Completethepartsreplacement.See“Completingthepartsreplacement”onpage172.
InstallingaServeRAIDSAS/SATAcontrollermemorymodule
Note:Forbrevity,inthisdocumentationtheLenovoServeRAIDSAS/SATAcontrollerisoftenreferredtoas
theSAS/SATAadapterortheServeRAIDadapter.
ToinstallaServeRAIDadaptermemorymodule,dothefollowing:
Step1.Turnofftheserver.Then,disconnectallexternalcablesandremoveallperipheraldevices.
Step2.Removetheservercover.See“Removingtheservercover”onpage88.
Step3.RemovethePCIriser-cardassembly.See“RemovingthePCIriser-cardassembly”onpage93.
Step4.RemovetheServeRAIDadapter.See“Removinganadapter”onpage110.
Step5.Touchthestatic-protectivepackagethatcontainsthememorymoduletoanyunpaintedmetal
surfaceontheserver;then,removethememorymodulefromthepackage.
Chapter7.Removingandinstallingservercomponents113