Step6.Aligntheboard-to-boardconnector1onthebottomofthememorymodulewiththeconnector2
ontheServeRAIDadapter.EnsurethatthethreemountingstudsontheServeRAIDadapterare
alignedwiththecorrespondingholesinthememorymodule.Carefullypressthememorymodule
ontotheServeRAIDadapteruntilthetwoconnectors(1and2)arefirmlyjoined.
Figure46.ServeRAIDadaptermemorymoduleinstallation
Step7.ReinstalltheServeRAIDadapter.See“Installinganadapter”onpage111.
Step8.Completethepartsreplacement.See“Completingthepartsreplacement”onpage172.
RemovingaRAIDadapterbatteryorflashpowermodule
Note:TheRAIDadapterbatteryorflashpowermoduleissupportedonthe2.5-inch-driveservermodelsonly.
ToremoveaRAIDadapterbatteryorflashpowermodule,dothefollowing:
Step1.Turnofftheserver.Then,disconnectallexternalcablesandremoveallperipheraldevices.
Step2.Removetheservercover.See“Removingtheservercover”onpage88.
114LenovoSystemx3250M6InstallationandServiceGuide