Step3.RemovetheRAIDadapterbatteryorflashpowermodule.
a.Removetheretainer.
b.Opentheretentionclip.
c.Pullthereleasetaboutward.
d.Liftthebatteryorflashpowermoduleuptoremovethebatteryorflashpowermodulefrom
theholder.
Figure47.RAIDadapterbatteryorflashpowermoduleremoval
Step4.Disconnectthecablefromthebatteryorflashpowermodule.
Step5.Completethepartsreplacement.See“Completingthepartsreplacement”onpage172.
InstallingaRAIDadapterbatteryorflashpowermodule
WhenyouinstallanyRAIDadapterthatcomeswithbatteriesorflashpowermodules,sometimesitis
necessarytoinstallthebatteriesorflashpowermodulesinanotherlocationintheservertopreventthe
batteriesorflashpowermodulesfromoverheating.Dependingonyourservermodel,abatterymustbe
installedremotelyneartheopticaldrivecageorthebackplane.
Note:TheRAIDadapterbatteryorflashpowermoduleissupportedonthe2.5-inch-driveservermodelsonly.
ToinstallaRAIDadapterbatteryorflashpowermoduleintheserver,dothefollowing:
Step1.Turnofftheserver.Then,disconnectallexternalcablesandremoveallperipheraldevices.
Step2.Removetheservercover.See“Removingtheservercover”onpage88.
Step3.RemovethePCIriser-cardassembly.See“RemovingthePCIriser-cardassembly”onpage93.
Step4.InstallaRAIDadapterinthePCIriser-cardassembly.See“Installinganadapteronpage111.