3.Disablememorymirroringandsparing.Ifthisactioneliminatesthemismatch,checktheIBM
Supportsiteforinformationrelatedtothisproblem.
4.UpdateUEFIfirmware.
5.ReplacetheDIMM.
6.Replacetheprocessor.
•S.51009[S.51009]
Explanation:Nosystemmemoryhasbeendetected.NoMemoryDetected
Severity
Error
UserResponse
Completethefollowingsteps:
1.Ifanymemoryerrorsareloggedotherthanthisone,takeactionsindicatedforthosecodesfirst.
2.Ifnoothermemorydiagnosticcodesappearinthelogs,verifythatallDIMMconnectorsare
enabledusingtheSetuputilityorLenovoToolsCenterSuiteCLIUtility.
3.Iftheproblemremains,shutdownandremovenodefromchassisandphysicallyverifythatone
ormoreDIMMsareinstalledandthatallDIMMsareinstalledinthecorrectpopulationsequence.
4.IfDIMMsarepresentandproperlyinstalled,checkforanylitDIMM-connectorLEDs,andif
found,reseatthoseDIMMs.
5.Reinstallnodeinchassis,poweronnode,thenchecklogsformemorydiagnosticcodes.
6.Iftheproblemremains,replacetheprocessor.
7.Iftheproblemremains,replacethesystemboard.
•S.58008[S.58008]
Explanation:ADIMMhasfailedthePOSTmemorytest.DIMMFailedMemoryTest
Severity
Error
UserResponse
Completethefollowingsteps:
1.YoumustAC-cyclethesystemtore-enabletheaffectedDIMMconnectororre-enablemanually
usingtheSetuputility.
2.Ifthecomputenodehasbeenrecentlyinstalled,serviced,moved,orupgraded,checktoensure
thatDIMMsarefirmlyseatedandthatnoforeignmaterialcanbeseenintheDIMMconnector.
Ifeitherconditionisobserved,correctandretrywiththesameDIMM.(Note:TheeventLog
mightcontainarecent00580A4eventdenotingdetectedchangeinDIMMpopulationthat
couldberelatedtothisproblem.)
3.Ifproblempersists,replacetheDIMMidentifiedbyLightPathand/oreventlogentry.
4.IfproblemrecursonthesameDIMMconnector,swaptheotherDIMMsonthesamememory
channelacrosschannelsoneatatimetoadifferentmemorychannelorprocessor.Ifproblem
followsamovedDIMMtoadifferentmemorychannel,replacethatDIMM.
5.ChecktheIBMsupportsiteforanapplicableservicebulletinorfirmwareupdatethatapplies
tothismemoryerror.
498LenovoSystemx3250M6InstallationandServiceGuide