FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblemis
solved.
Ifanactionstepisprecededby“(Trainedtechnicianonly),thatstepmustbeperformedonlybyatrained
technician.
Gotothesupportwebsiteathttp://www.lenovo.com/supporttocheckfortechnicalinformation,hints,tips,
andnewdevicedriversortosubmitarequestforinformation.
SymptomAction
6.(Trainedtechnicianonly)replacethesystemboard(see“Removingthesystem
board”onpage283and“Replacingthesystemboard”onpage286).
7.ReinstalltheMicroprocessor1;then,restartingtheserver.IfthePwrrailGerror
hasbeenrecordedinthesystemeventlogagain,theProcessorthatyoujust
reinstalledisdefective.ReplacethedefectiveProcessor.
(Trainedtechnicianonly)Microprocessor1(See“Removingamicroprocessor
andheatsink”onpage267and“Replacingamicroprocessorandheatsink”
onpage273).
ThePwrrailHerrorhasbeen
recordedinthesystemevent
log.
1.Disconnecttheserverpowercords.
2.RemovethefollowingcomponentsifthePwrrailHerrorhasbeenrecordedin
thesystemeventlog:
Harddiskdrivesatbackplaneassembly3
Harddiskdrivebackplaneassembly3
PCIeSolidstatedrives
PCIeSolidstatedrivebackplaneassembly
3.Restarttheserver.IfthePwrrailHerrorhasbeenrecordedinthesystemevent
logagain,(trainedtechnicianonly)replacethesystemboard(see“Removingthe
systemboard”onpage283and“Replacingthesystemboard”onpage286).
4.Reinstallthecomponentsoneatatime,intheordershown,restartingthe
servereachtime.IfthePwrrailHerrorhasbeenrecordedinthesystemevent
logagain,thecomponentthatyoujustreinstalledisdefective.Replacethe
defectivecomponent.
Harddiskdrivebackplaneassembly3
Harddiskdrivesatbackplaneassembly3
PCIeSolidstatedrivebackplaneassembly
PCIeSolidstatedrives
ThePwrrailIerrorhasbeen
recordedinthesystemevent
log.
1.Disconnecttheserverpowercords.
2.RemovethefollowingcomponentsifthePwrrailIerrorhasbeenrecordedin
thesystemeventlog:
Harddiskdrivesatbackplaneassembly1and/orbackplaneassembly2
Harddiskdrivebackplaneassembly1and/orbackplaneassembly2
3.Restarttheserver.IfthePwrrailIerrorhasbeenrecordedinthesystemevent
logagain,(trainedtechnicianonly)replacethesystemboard(see“Removingthe
systemboard”onpage283
and“Replacingthesystemboard”onpage286).
4.Reinstallthecomponentsoneatatime,intheordershown,restartingthe
servereachtime.IfthePwrrailIerrorhasbeenrecordedinthesystemevent
logagain,thecomponentthatyoujustreinstalledisdefective.Replacethe
defectivecomponent.
Harddiskdrivebackplaneassembly1and/orbackplaneassembly2
Harddiskdrivesatbackplaneassembly1and/orbackplaneassembly2