Note:OnlytheMACaddressthatiscurrentlyinuseisdisplayed(dedicatedorshared)
–IMMsharedMACaddress
–IPv4information
–IPv6address
•Systemenvironmentalinformation:
–Ambienttemperature
–CPUtemperature
–ACinputvoltage
–Estimatedpowerconsumption
Rearview
Thefollowingillustrationshowstheconnectorsontherearoftheserver.
Figure19.Rearview
•NMIbutton:Pressthisbuttontoforceanonmaskableinterrupttothemicroprocessor.Itallowsyouto
bluescreentheserverandtakeamemorydump(usethisbuttononlywhendirectedbytheservice
support).Youmighthavetouseapenortheendofastraightenedpapercliptopressthebutton.The
NMIbuttonisinthelowerleft-handcornerontherearoftheserver.
•Powerconnector:Connectthepowercordtothisconnector.
Note:Powersupply1isthedefault/primarypowersupply.Ifpowersupply1fails,youmustreplaceit
immediately.
•Videoconnector:Connectamonitortothisconnector.Thevideoconnectorsonthefrontandrearof
theservercanbeusedsimultaneously.
Note:Themaximumvideoresolutionis1600x1200at75Hz.
•EightUniversalSerialBus(USB)connectors:ConnectaUSBdevice,suchasaUSBmouseor
keyboardtoanyoftheseconnectors.EightUniversalSerialBusprovides2.0and3.0ports.
•Systems-managementEthernetconnector:Usethisconnectortoconnecttheservertoanetworkfor
fullsystems-managementinformationcontrol.ThisconnectorisusedonlybytheIMM2.1.Adedicated
managementnetworkprovidesadditionalsecuritybyphysicallyseparatingthemanagementnetwork
trafficfromtheproductionnetwork.YoucanusetheSetuputilitytoconfiguretheservertousea
dedicatedsystemsmanagementnetworkorasharednetwork.SeeUsingtheSetuputilityintheProblem
DeterminationandServiceGuideformoreinformation.
•Ethernetconnectors:Useeitheroftheseconnectorstoconnecttheservertoanetwork.Whenyou
enablesharedEthernetforIMM2.1intheSetuputility,youcanaccesstheIMM2.1usingeitherthe
Ethernet1orthesystem-managementEthernet(default)connector.SeeUsingtheSetuputilityfor
moreinformation.
Chapter1.TheSystemx3650M5server23