Table5.SystempulseLEDs(continued)
LEDDescriptionAction
power-controlbuttontopower-onthe
server.
4.IfthisLEDdoesnotblinkwithin30seconds
ofconnectingapowersourcetotheserver,
(trainedtechnicianonly)replacethesystem
board.
PCIriser-cardLEDs
ThefollowingillustrationshowsthelocationofthePCIriser-cardLEDs.
Figure46.PCIriser-cardLEDs
Eventlogs
ErrorcodesandmessagesdisplayedinPOSTeventlog,system-eventlog,integratedmanagementmodule
(IMM2)eventlog,andDSAeventlog.
•POSTeventlog:Thislogcontainsthemostrecenterrorcodesandmessagesthatweregenerated
duringPOST.YoucanviewthecontentsofthePOSTeventlogfromtheSetuputility(see“Startingthe
Setuputility”onpage47
).FormoreinformationaboutPOSTerrorcodes,seeAppendixB“UEFI/POST
diagnosticcodes”onpage1031.
•System-eventlog:ThislogcontainsPOSTandsystemmanagementinterrupt(SMI)eventsandall
eventsthataregeneratedbythebaseboardmanagementcontrollerthatisembeddedintheintegrated
managementmodule(IMM).Youcanviewthecontentsofthesystem-eventlogthroughtheSetup
utilityandthroughtheDynamicSystemAnalysis(DSA)program(asIPMIeventlog).Thesystem-event
logislimitedinsize.Whenitisfull,newentrieswillnotoverwriteexistingentries;therefore,youmust
periodicallyclearthesystem-eventlogthroughtheSetuputility.Whenyouaretroubleshootinganerror,
youmighthavetosaveandthenclearthesystem-eventlogtomakethemostrecenteventsavailablefor
analysis.Formoreinformationaboutthesystem-eventlog,seeAppendixA“Integratedmanagement
moduleII(IMM2)errormessages”onpage315
.
Messagesarelistedontheleftsideofthescreen,anddetailsabouttheselectedmessagearedisplayed
ontherightsideofthescreen.Tomovefromoneentrytothenext,usetheUpArrow(↑)andDown
Arrow(↓)keys.
SomeIMMsensorscauseassertioneventstobeloggedwhentheirsetpointsarereached.Whena
setpointconditionnolongerexists,acorrespondingdeassertioneventislogged.However,notallevents
areassertion-typeevents.
Chapter3.Troubleshooting75