EasyManua.ls Logo

Lenovo x3650 M5 - Page 1105

Lenovo x3650 M5
1242 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.Rerunthetest.
3.Iffailureremains,referto"Troubleshootingbysymptom"inthesystem"InstallationandService
Guide"forthenextcorrectiveaction.
Relatedlinks
IBMSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
406-903-000:IANet:InterruptsTestFailed
AfailurewasdetectedduringtheInterrupttest.
Recoverable
No
Severity
Error
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Completethefollowingsteps:
1.Checkcomponentfirmwarelevelandupgradeifnecessary.Theinstalledfirmwarelevelcanbe
foundintheDSADiagnosticEventLogwithintheFirmware/VPDsectionforthiscomponent.
2.Rerunthetest.
3.CheckinterruptassignmentsinthePCIHardwaresectionoftheDSADiagnosticLog.Ifthe
ethernetdeviceissharinginterrupts,ifpossiblemodifytheinterruptassignmentsusingF1
Setuptoassignauniqueinterrupttothedevice.
4.Rerunthetest.
5.Iffailureremains,referto"Troubleshootingbysymptom"inthesystem"InstallationandService
Guide"forthenextcorrectiveaction.
Relatedlinks
IBMSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
406-904-000:IANet:LoopbackTestFailed
AfailurewasdetectedduringtheLoopbacktest.
Recoverable
No
Severity
Error
Serviceable
AppendixC.DSAdiagnostictestresults1093

Table of Contents

Related product manuals