Mechanical installation
Standard devices in a power range of 0.25 ... 3 kW
Mounting in "cold plate" technique
5
l
105
EDS84ASC552 EN 8.1
TopLine
8400GG105d
Fig. 5−13 Device dimensions
h b t h
1
h
2
b
1
t
1
t
2
g
1
g
2
[kW] [mm]
E84AVTCC551xxX0
0.55
215 102 178 236 276 70 165 205 6 5
E84AVTCC751xxX0
0.75
E84AVTCC112xxX0
1.1
270 137 178 295 335 70 165 205 6 5
E84AVTCC152xxX0
1.5
E84AVTCC222xxX0
2.2
E84AVTCC551xxB0
0.55
215 102 198 236 276 70 185 225 6 5
E84AVTCC751xxB0
0.75
E84AVTCC112xxB0
1.1
270 137 198 295 335 70 185 225 6 5
E84AVTCC152xxB0
1.5
E84AVTCC222xxB0
2.2